NetView Started Task name must be properly identified/defined to the system ACP.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-224331 | ZNETA030 | SV-224331r1144120_rule | CCI-000764 | medium |
| Description | ||||
| NetView requires a started task(s) that will be restricted to certain resources, datasets, and other system functions. Defining the started task as a userid to the system ACP allows the ACP to control the access and authorized users that require these capabilities. Failure to properly control these capabilities could compromise the operating system environment, ACP, and customer data. | ||||
| STIG | Date | |||
| z/OS NetView for ACF2 Security Technical Implementation Guide | 2025-09-26 | |||
Related Frameworks
4 paths across 3 frameworks
Related Frameworks
NIST 800-531 mapping
IA-2
1.00
- DISA · V7R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.5.1
1.00
- DISA · V7R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.5.2
1.00
- DISA · V7R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000764
1.00
- DISA · V7R2 · disa_xccdf · related
Details
Check Text (C-224331r1144120_chk)
Refer to the following report produced by the ACF2 Data Collection:
- ACF2CMDS.RPT(ATTSTC).
Verify that the logonid(s) for the NetView started task(s) is (are) properly defined. If the following attributes are defined, this is not a finding.
STC
MUSASS
NO-SMC
Fix Text (F-25996r1144119_fix)
The NetView systems programmer and the ISSO will ensure that a product's Started Task(s) is properly identified/defined to the System ACP.
If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.
Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.
Example:
SET LID
CHANGE NETVIEW STC MUSASS NO-SMC