STIGViewer Support

Virtual machines (VMs) must disable DirectPath I/O devices when not required.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-258727VMCH-80-000214SV-258727r959010_ruleCCI-000366medium
Description
VMDirectPath I/O (PCI passthrough) enables direct assignment of hardware PCI functions to VMs. This gives the VM access to the PCI functions with minimal intervention from the ESXi host. This is a powerful feature for legitimate applications such as virtualized storage appliances, backup appliances, dedicated graphics, etc., but it also allows a potential attacker highly privileged access to underlying hardware and the PCI bus.
STIGDate
VMware vSphere 8.0 Virtual Machine Security Technical Implementation Guide2026-08-26

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (8) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-01Configuration Management Program
1.00
END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
CFG-02Secure Baseline Configurations
0.50
CFG-02.7Approved Configuration Deviations
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (100) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-12Session Termination
1.00
AC-16(1)Dynamic Attribute Association
1.00
AC-17(1)Monitoring and Control
1.00
AC-2Account Management
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-24(1)Transmit Access Authorization Information
1.00
AC-25Reference Monitor
1.00

+90 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.4.1
1.00
3.4.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

PR.PSPlatform Security
0.50

Who does this work

10 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-258727r959010_chk)

For each virtual machine do the following: From the vSphere Client, view the Summary tab. Review the PCI devices section and verify none exist. or From a PowerCLI command prompt while connected to the ESXi host or vCenter server, run the following command: Get-VM "VM Name" | Get-PassthroughDevice If the virtual machine has passthrough devices present, and the specific device returned is not approved, this is a finding.

Fix Text (F-62376r933241_fix)

From the vSphere Client, select the Virtual Machine, right-click and go to Edit Settings >> Virtual Hardware tab. Find the unexpected PCI device returned from the check. Hover the mouse over the device and click the circled "X" to remove the device. Click "OK". or From a PowerCLI command prompt while connected to the ESXi host or vCenter server, run the following command: Get-VM "VM Name" | Get-PassthroughDevice | Remove-PassthroughDevice