STIGViewer Support

The vCenter Server must only send NetFlow traffic to authorized collectors.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-258938VCSA-80-000271SV-258938r961863_ruleCCI-000366medium
Description
The distributed virtual switch can export NetFlow information about traffic crossing the switch. NetFlow exports are not encrypted and can contain information about the virtual network, making it easier for a man-in-the-middle attack to be executed successfully. If NetFlow export is required, verify that all NetFlow target Internet Protocols (IPs) are correct.
STIGDate
VMware vSphere 8.0 vCenter Security Technical Implementation Guide2026-05-23

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (8) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-01Configuration Management Program
1.00
END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
CFG-02Secure Baseline Configurations
0.50
CFG-02.7Approved Configuration Deviations
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (100) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-12Session Termination
1.00
AC-16(1)Dynamic Attribute Association
1.00
AC-17(1)Monitoring and Control
1.00
AC-2Account Management
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-24(1)Transmit Access Authorization Information
1.00
AC-25Reference Monitor
1.00

+90 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.4.1
1.00
3.4.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

PR.PSPlatform Security
0.50

Who does this work

10 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-258938r961863_chk)

If distributed switches are not used, this is not applicable. To view NetFlow Collector IPs configured on distributed switches: From the vSphere Client, go to "Networking". Select a distributed switch >> Configure >> Settings >> NetFlow. View the NetFlow pane and verify any collector IP addresses are valid and in use for troubleshooting. or From a PowerCLI command prompt while connected to the vCenter server, run the following command: Get-VDSwitch | select Name,@{N="NetFlowCollectorIPs";E={$_.ExtensionData.config.IpfixConfig.CollectorIpAddress}} To view if NetFlow is enabled on any distributed port groups: From the vSphere Client, go to "Networking". Select a distributed port group >> Manage >> Settings >> Policies. Go to "Monitoring" and view the NetFlow status. or From a PowerCLI command prompt while connected to the vCenter server, run the following command: Get-VDPortgroup | Select Name,VirtualSwitch,@{N="NetFlowEnabled";E={$_.Extensiondata.Config.defaultPortConfig.ipfixEnabled.Value}} If NetFlow is configured and the collector IP is not known and documented, this is a finding.

Fix Text (F-62587r934471_fix)

To remove collector IPs, do the following: From the vSphere Client, go to "Networking". Select a distributed switch >> Configure >> Settings >> NetFlow. Click "Edit". Remove any unknown collector IPs. or From a PowerCLI command prompt while connected to the vCenter server, run the following commands: $dvs = Get-VDSwitch dvswitch | Get-View ForEach($vs in $dvs){ $spec = New-Object VMware.Vim.VMwareDVSConfigSpec $spec.configversion = $vs.Config.ConfigVersion $spec.IpfixConfig = New-Object VMware.Vim.VMwareIpfixConfig $spec.IpfixConfig.CollectorIpAddress = "" $spec.IpfixConfig.CollectorPort = "0" $spec.IpfixConfig.ActiveFlowTimeout = "60" $spec.IpfixConfig.IdleFlowTimeout = "15" $spec.IpfixConfig.SamplingRate = "0" $spec.IpfixConfig.InternalFlowsOnly = $False $vs.ReconfigureDvs_Task($spec) } Note: This will reset the NetFlow collector configuration back to the defaults. To disable NetFlow on a distributed port group, do the following: From the vSphere Client, go to "Networking". Select a distributed port group >> Configure >> Settings >> Policies. Click "Edit". Click the "Monitoring" tab. Change "NetFlow" to "Disabled". or From a PowerCLI command prompt while connected to the vCenter server, run the following commands: $pgs = Get-VDPortgroup | Get-View ForEach($pg in $pgs){ $spec = New-Object VMware.Vim.DVPortgroupConfigSpec $spec.configversion = $pg.Config.ConfigVersion $spec.defaultPortConfig = New-Object VMware.Vim.VMwareDVSPortSetting $spec.defaultPortConfig.ipfixEnabled = New-Object VMware.Vim.BoolPolicy $spec.defaultPortConfig.ipfixEnabled.inherited = $false $spec.defaultPortConfig.ipfixEnabled.value = $false $pg.ReconfigureDVPortgroup_Task($spec) }