The VMM must provide an immediate warning to the SA and ISSO, at a minimum, when allocated audit record storage volume reaches 75% of repository maximum audit record storage capacity.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-207454SRG-OS-000343-VMM-001240SV-207454r971542_ruleCCI-001855medium
Description
If security personnel are not notified immediately when storage volume reaches 75%, they are unable to plan for audit record storage capacity expansion.
STIGDate
Virtual Machine Manager Security Requirements Guide2024-12-06

Related Frameworks

2 paths across 2 frameworks
NIST 800-531 mapping
  • DISA · 2 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
CCI1 mapping
CCI-001855
1.00
  • DISA · 2 · disa_xccdf · related

Details

Check Text (C-207454r971542_chk)

Verify the VMM provides an immediate warning to the SA and ISSO, at a minimum, when allocated audit record storage volume reaches 75% of repository maximum audit record storage capacity. If it does not, this is a finding.

Fix Text (F-7711r365767_fix)

Configure the VMM to provide an immediate warning to the SA and ISSO, at a minimum, when allocated audit record storage volume reaches 75% of repository maximum audit record storage capacity.