STIGViewer Support

The VMM must synchronize internal information system clocks to the authoritative time source when the time difference is greater than one second.

Export this STIG:

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-207464SRG-OS-000356-VMM-001340SV-207464r984238_ruleCCI-004926medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronizing internal VMM clocks provides uniformity of time stamps for VMMs with multiple system clocks and systems connected over a network.
STIGDate
Virtual Machine Manager Security Requirements Guide2026-09-04

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (6) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-207464r984238_chk)

Verify the VMM synchronizes internal information system clocks to the authoritative time source when the time difference is greater than one second. If it does not, this is a finding.

Fix Text (F-7721r365797_fix)