STIGViewer Support

TOSS 5 must securely compare internal information system clocks at least every 24 hours.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-282549TOSS-05-000202SV-282549r1262431_ruleCCI-002322medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Depending on the infrastructure being used the "pool" directive may not be supported. Authoritative time sources include the United States Naval Observatory (USNO) time servers, a time server designated for the appropriate DoW network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS). Satisfies: SRG-OS-000298-GPOS-00116, SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144, SRG-OS-000359-GPOS-00146
STIGDate
Tri-Lab Operating System Stack (TOSS) 5 Security Technical Implementation Guide2026-08-20

Related Frameworks

4 mappings across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NET-14.8Expeditious Disconnect / Disable Capability
1.00
MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (49) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-17(9)Disconnect or Disable Access
1.00
AC-18(1)Authentication and Encryption
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-3(13)Attribute-based Access Control
1.00
AC-3(4)Discretionary Access Control
1.00

+39 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI4 mappings

Details

Check Text (C-282549r1262431_chk)

Verify TOSS 5 is securely comparing internal information system clocks at least every 24 hours with an NTP server with the following commands: $ sudo grep maxpoll /etc/chrony.conf server 0.us.pool.ntp.mil iburst maxpoll 16 If the "maxpoll" option is set to a number greater than 16 or the line is commented out, this is a finding. Verify the "chrony.conf" file is configured to an authoritative DoW time source using the following command: $ sudo grep -i server /etc/chrony.conf server 0.us.pool.ntp.mil If the parameter "server" is not set or is not set to an authoritative DoW time source, this is a finding.

Fix Text (F-87015r1200626_fix)

Configure TOSS 5 to securely compare internal information system clocks at least every 24 hours with an NTP server by adding/modifying the following line in the /etc/chrony.conf file: server [ntp.server.name] iburst maxpoll 16