TOSS 5 chronyd service must be enabled.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-282575TOSS-05-000201SV-282575r1200705_ruleCCI-004923medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network.
STIGDate
Tri-Lab Operating System Stack (TOSS) 5 Security Technical Implementation Guide2026-04-01

Details

Check Text (C-282575r1200705_chk)

Verify the "chronyd" service is active using the following command: $ systemctl is-active chronyd active If the "chronyd" service is not active, this is a finding.

Fix Text (F-87041r1200704_fix)

Enable the "chronyd" service using the following command: $ sudo systemctl enable --now chronyd