STIGViewer Support

The Tanium Operating System (TanOS) must synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-254866TANS-OS-001100SV-254866r1067750_ruleCCI-004926medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations must consider setting time periods for different types of systems (e.g., financial, legal, or mission-critical systems). Organizations should also consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). This requirement is related to the comparison done every 24 hours in CCI-001891 because a comparison must be done to determine the time difference.
STIGDate
Tanium 7.x Operating System on TanOS Security Technical Implementation Guide2025-02-11

Related Frameworks

2 mappings across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (6) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI2 mappings

Details

Check Text (C-254866r1067750_chk)

1. Access the Tanium Server interactively. 2. Log on to the TanOS server with the tanadmin role. 3. Press "A" for "Appliance Configuration Menu," and then press "Enter". 4. Press "3" for "NTP Configuration," and then press "Enter". If there is no address listed for "Currently configured ntp servers:", this is a finding. The status is reported differently in different versions of TanOS. TanOS <= 1.7.1: If the "Current NTP Status" does not list a status of "Synchronized to NTP Server ( ) at stratum #" and "Time correct to within # ms", this is a finding. TanOS >= 1.7.2: If the "Current NTP Status" does not list a status of "Normal", this is a finding.

Fix Text (F-58423r1067749_fix)

1. Access the Tanium Server interactively. 2. Log on to the TanOS server with the tanadmin role. 3. Press "A" for "Appliance Configuration Menu," and then press "Enter". 4. Press "3" for "NTP Configuration," and then press "Enter". 5. Type "Yes" to "Remove the current NTP servers and enter new information?" and then press "Enter". 6. Type the first NTP server address and then press "Enter". 7. Type "Yes" to provide a second NTP Server, and then press "Enter". 8. Type the second NTP server address and then press "Enter". 9. Press "Enter" to return to the "Appliance Configuration" menu.