STIGViewer Support

The Tanium Operating System (TanOS) must enforce a 60-day maximum password lifetime restriction.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-254844TANS-OS-000275SV-254844r1038967_ruleCCI-004066medium
Description
Any password, no matter how complex, can eventually be cracked. Therefore, passwords need to be changed periodically. One method of minimizing this risk is to use complex passwords and periodically change them. If the operating system does not limit the lifetime of passwords and force users to change their passwords, there is the risk that the operating system passwords could be compromised.
STIGDate
Tanium 7.x Operating System on TanOS Security Technical Implementation Guide2025-02-11

Related Frameworks

2 mappings across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-10Authenticator Management
0.50
IAC-10.1Password-Based Authentication
0.50
IAC-10.4Automated Support For Password Strength
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (63) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-12Session Termination
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00

+53 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.5.10
1.00
3.5.7
1.00
3.5.8
1.00
3.5.9
1.00
CCI2 mappings

Details

Check Text (C-254844r1038967_chk)

1. Access the Tanium Server interactively. 2. Log on to the TanOS server with the tanadmin role. 3. Press "C" for "User Administration Menu". 4. Press "L" for "Local Tanium User Management". 5. Press "B" for "Security Policy Local Authentication Service". If the "Password Maximum Age (days)" is not set to "60", this is a finding.

Fix Text (F-58401r866072_fix)

1. Access the Tanium Server interactively. 2. Log on to the TanOS server with the tanadmin role. 3. Press "C" for "User Administration Menu". 4. Press "L" for "Local Tanium User Management". 5. Press "B" for "Security Policy Local Authentication Service". 6. Type "Yes". 7. Press "Enter" to accept the current value for "Define the minimum password in days [0 - 20]". 8. Set the value of "Define the maximum password lifetime in days [0-300]" to "60". 9. Press "Enter" to accept the current values for the rest of the options. 10. Type "Yes" to apply the new security policy.