The Tanium application must set an inactive timeout for sessions.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-254927TANS-AP-000720SV-254927r1067716_ruleCCI-002361medium
Description
Leaving sessions open indefinitely is a major security risk. An attacker can easily use an already authenticated session to access the hosted application as the previously authenticated user. By closing sessions after a set period of inactivity, the web server can make certain that sessions not closed through the user logging out of an application are eventually closed. Acceptable values are 5 minutes for high-value applications, 10 minutes for medium-value applications, and 20 minutes for low-value applications.
STIGDate
Tanium 7.x Application on TanOS Security Technical Implementation Guide2025-02-11

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (6) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-01.2Authenticate, Authorize and Audit (AAA)
1.00
IAC-02Identification & Authentication for Organizational Users
1.00
IAC-03Identification & Authentication for Non-Organizational Users
1.00
IAC-04Identification & Authentication for Devices
1.00
IAC-05Identification & Authentication for Third-Party Technology Assets, Applications and/or Services (TAAS)
1.00
IAC-25Session Termination
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (30) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-11Device Lock
1.00
AC-11(1)Pattern-hiding Displays
1.00
AC-12Session Termination
1.00
AC-12(1)User-initiated Logouts
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00

+20 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.1.11
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

7 NICE work roles and 5 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-254927r1067716_chk)

1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multifactor authentication. 2. Click "Administration" on the top navigation banner. 3. Under "Configuration", select "Settings". 4. Click the "Advanced Settings" tab. 5. In "Filter Items" box, enter "max_console_idle_seconds". 6. Click "Enter". If no results are returned, this is a finding. If results are returned for "max_console_idle_seconds", but the value is not "900" or less, this is a finding.

Fix Text (F-58484r1067715_fix)

In the event the "max_console_idle_seconds" setting exists, but is not "900" or less: 1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multifactor authentication. 2. Click "Administration" on the top navigation banner. 3. Under "Configuration", select "Settings". 4. Click the "Advanced Settings" tab. 5. In the "Filter Items" box, enter "max_console_idle_seconds". 6. Select the "max_console_idle_seconds" setting. 7. Enter "900" or less for "Value". 8. Click "Save". In the event the "max_console_idle_seconds" setting does not exist: 1. Using a web browser on a system that has connectivity to the Tanium Application, access the Tanium Application web user interface (UI) and log on with multifactor authentication. 2. Click "Administration" on the top navigation banner. 3. Under "Configuration", select "Settings". 4. Click the "Advanced Settings" tab. 5. Click "Create Setting" in the top right. 6. Select "Server" for "Setting Type". 7. In "Create Platform Setting" dialog box, enter "max_console_idle_seconds" for "Name". 8. Select "Numeric" for the "Value Type". 9. Enter "900" or less for the "Value". 10. Click "Save".