STIGViewer Support

The Tanium application must enforce a 60-day maximum password lifetime restriction.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-254913TANS-AP-000475SV-254913r1043190_ruleCCI-004066medium
Description
Any password, no matter how complex, can eventually be cracked. Therefore, passwords need to be changed at specific intervals. One method of minimizing this risk is to use complex passwords and periodically change them. If the application does not limit the lifetime of passwords and force users to change their passwords, there is the risk that the system and/or application passwords could be compromised. This requirement does not include emergency administration accounts which are meant for access to the application in case of failure. These accounts are not required to have maximum password lifetime restrictions.
STIGDate
Tanium 7.x Application on TanOS Security Technical Implementation Guide2025-02-11

Related Frameworks

2 mappings across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-10Authenticator Management
0.50
IAC-10.1Password-Based Authentication
0.50
IAC-10.4Automated Support For Password Strength
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (63) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-12Session Termination
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00

+53 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.5.10
1.00
3.5.7
1.00
3.5.8
1.00
3.5.9
1.00
CCI2 mappings

Details

Check Text (C-254913r1043190_chk)

Console Users: Per guidance, Enterprise Console users are inherited via LDAP synchronization as such passwords are not managed or enforced at the Tanium application level. Local TanOS account: 1. Access the Tanium Server interactively. 2. Log on to the TanOS server with the tanadmin role. 3. Enter "C" for "User Administration Menu," and then press "Enter". 4. Enter "L" for " Local Tanium User Management," and then press "Enter". 5. Enter "B" for " Security Policy Local Authentication Service," and then press "Enter". If the value of "Password Maximum Age (days):" is greater than "60", this is a finding.

Fix Text (F-58470r867638_fix)

Console Users: Per guidance, Enterprise Console users are inherited via LDAP synchronization as such passwords are not managed or enforced at the Tanium application level. Local TanOS account: 1. Access the Tanium Server interactively. 2. Log on to the TanOS server with the tanadmin role. 3. Enter "" for "User Administration Menu," and then press "Enter". 4. Enter "L" for "Local Tanium User Management," and then press "Enter". 5. Enter "B" for "Security Policy Local Authentication Service," and then press "Enter". 6. Type "yes," and then press "Enter". 7. Input the following settings, pressing "Enter" after every value: a) Minimum Password Lifetime - 1 b) Maximum Password Lifetime - 60 c) Minimum Password Length - 15 d) Minimum Password History - 5 e) Password Lockout - TRUE f) Maximum Password Attempts - 3 8. Type "yes" to accept the new password policy.