STIGViewer Support

The Edge SWG must require that when a password is changed, the characters are changed in at least eight of the positions within the password.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-279263SYME-ND-000650SV-279263r1170553_ruleCCI-004066medium
Description
If the application allows the user to consecutively reuse extensive portions of passwords, this increases the chances of password compromise by increasing the window of opportunity for attempts at guessing and brute-force attacks. The number of changed characters refers to the number of changes required with respect to the total number of positions in the current password. In other words, characters may be the same within the two passwords; however, the positions of the like characters must be different. Multifactor authentication (MFA) is required for all administrative and user accounts on network devices, except for an account of last resort and (where applicable) a root account. Passwords should only be used when MFA using PKI is not available, and for the account of last resort and root account.
STIGDate
Symantec Edge SWG NDM Security Technical Implementation Guide2026-02-25

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-10Authenticator Management
0.50
IAC-10.1Password-Based Authentication
0.50
IAC-10.4Automated Support For Password Strength
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (61) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-12Session Termination
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00

+51 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.5.10
1.00
3.5.7
1.00
3.5.8
1.00
3.5.9
1.00
CCI1 mapping

Details

Check Text (C-279263r1170553_chk)

1. Log in to the Edge SWG SSH CLI. 2. Enter "show configuration". 3. Move down the configuration to the "security password-policy" section. If the configuration "security password-policy min-changes" is not set to "8", this is a finding.

Fix Text (F-83718r1170552_fix)

1. Log in to the Edge SWG SSH CLI. 2. Enter "enable" and "configure terminal". 3. Enter "security password-policy min-changes 8". 4. Enter "security password-policy min-groups 4".