The Edge SWG must fail securely in the event of an operational failure.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-279222SYME-00-010200SV-279222r1170676_ruleCCI-001126medium
Description
If a boundary protection device fails in an unsecure manner (open), information external to the boundary protection device may enter, or the device may permit unauthorized information release. Secure failure ensures when a boundary control device fails, all traffic will be subsequently denied. Fail secure is a condition achieved by employing information system mechanisms to ensure, in the event of operational failures of boundary protection devices at managed interfaces (e.g., routers, firewalls, guards, and application gateways residing on protected subnetworks commonly referred to as demilitarized zones), information systems do not enter into unsecure states where intended security properties no longer hold.
STIGDate
Symantec Edge SWG ALG Security Technical Implementation Guide2025-12-16

Details

Check Text (C-279222r1170676_chk)

1. Log in to the Integrated Secure Gateway (ISG) SSH CLI. 2. Enter "enable" and "configure terminal". 3. Enter "bridge view". If the mode for the bridge in use does not state "fail-closed", this is a finding.

Fix Text (F-83675r1170649_fix)

1. Log in to the Integrated Secure Gateway (ISG) SSH CLI. 2. Enter "enable" and "configure terminal". 3. Enter "bridge view". 4. Find the bridge in use for the Edge SWG, e.g., "passthru-2:0". 5. Enter "bridge edit passthru-2:0 mode fail-closed".