STIGViewer Support

SLEM 5 clock must, for networked systems, be synchronized to an authoritative DOD time source at least every 24 hours.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-261311SLEM-05-252010SV-261311r1038944_ruleCCI-001891medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
STIGDate
SUSE Linux Enterprise Micro (SLEM) 5 Security Technical Implementation Guide2025-05-08

Related Frameworks

2 mappings across 3 frameworks
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI2 mappings

Details

Check Text (C-261311r1038944_chk)

Verify that SLEM 5 clock must be configured to synchronize to an authoritative DOD time source when the time difference is greater than one second with the following command: > sudo grep maxpoll /etc/chrony.conf server 0.us.pool.ntp.mil maxpoll 16 If the "server" parameter is not set to an authoritative DOD time source, "maxpoll" is greater than "16", the line is commented out, or the line is missing, this is a finding.

Fix Text (F-64948r996403_fix)

SLEM 5 clock must be configured to synchronize to an authoritative DOD time source when the time difference is greater than one second. To configure the system clock to synchronize to an authoritative DOD time source at least every 24 hours, edit the file "/etc/chrony.conf". Add or correct the following lines by replacing "<time_source>" with an authoritative DOD time source: server <time_source> maxpoll 16