SLEM 5 auditd service must notify the system administrator (SA) and information system security officer (ISSO) immediately when audit storage capacity is 75 percent full.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-261414SLEM-05-653030SV-261414r996654_ruleCCI-001855medium
Description
If security personnel are not notified immediately when storage volume reaches 75 percent utilization, they are unable to plan for audit record storage capacity expansion.
STIGDate
SUSE Linux Enterprise Micro (SLEM) 5 Security Technical Implementation Guide2026-02-10

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-05.2Event Log Storage Capacity Alerting
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (11) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AU-12Audit Record Generation
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-4Audit Log Storage Capacity
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-5(1)Storage Capacity Warning
1.00
AU-5(2)Real-time Alerts
1.00
AU-7Audit Record Reduction and Report Generation
1.00
AU-9(3)Cryptographic Protection
1.00

+1 more (top 10 by confidence shown)

CCI1 mapping

Details

Check Text (C-261414r996654_chk)

Determine if SLEM 5 auditd is configured to notify the SA and ISSO when the audit record storage volume reaches 75 percent of the storage capacity with the following command: > sudo grep -iw space_left /etc/audit/auditd.conf space_left = 25% If "space_left" is not set to "25%" or greater, this is a finding.

Fix Text (F-65051r996108_fix)

Configure SLEM 5 auditd service to notify the SA and ISSO immediately when audit storage capacity is 75 percent full. Add or modify the following lines in the "/etc/audit/auditd.conf " file: space_left = 25%