The SEL-2740S must alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-92293SELS-ND-000340SV-102381r1_ruleCCI-000139medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without this notification, the security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Audit processing failures include software/hardware errors, failures in the audit capturing mechanisms, and audit storage capacity being reached or exceeded.
STIGDate
SEL-2740S NDM Security Technical Implementation Guide2019-05-06

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-05Response To Event Log Processing Failures
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (20) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(4)Automated Audit Actions
1.00
AU-10Non-repudiation
1.00
AU-12Audit Record Generation
1.00
AU-12(1)System-wide and Time-correlated Audit Trail
1.00
AU-14(1)System Start-up
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-5(1)Storage Capacity Warning
1.00
AU-5(2)Real-time Alerts
1.00
AU-6(4)Central Review and Analysis
1.00

+10 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.4
1.00
CCI1 mapping

Details

Check Text (C-102381r1_chk)

Review the configuration node of the SEL-2740S in the flow controller and verify the alarm contact behavior is configured as a log service under All Categories in the configuration object for the desired switch. If the switch is not configured to alert the ISSO and SA in the event of an audit processing failure, this is a finding.

Fix Text (F-98531r1_fix)

On commissioning the SEL-2740S, enter the IP address, subnet mask, flow controller IP address, default gateway, and host name. Select the severity level desired for the alarm contact in the log services for the configuration node.