STIGViewer Support

The Samsung SDS EMM local accounts must be configured with password maximum lifetime of 60 Days.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-245528SSDS-00-200210SV-245528r836815_ruleCCI-000174medium
Description
Any password, no matter how complex, can eventually be cracked. Therefore, passwords need to be changed at specific intervals. One method of minimizing this risk is to use complex passwords and periodically change them. If the application does not limit the lifetime of passwords and force users to change their passwords, there is the risk that the system and/or application passwords could be compromised. This requirement does not include emergency administration accounts which are meant for access to the application in case of failure. These accounts are not required to have maximum password lifetime restrictions. SFR ID: FMT_SMF.1(2)b. / IA-5 (1) (d)
STIGDate
Samsung SDS EMM Security Technical Implementation Guide2022-06-10

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-02.7System-Wide / Time-Correlated Audit Trail
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (7) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AU-10Non-repudiation
1.00
AU-12Audit Record Generation
1.00
AU-12(1)System-wide and Time-correlated Audit Trail
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-7Audit Record Reduction and Report Generation
1.00
AU-9(2)Store on Separate Physical Systems or Components
1.00
CCI1 mapping

Details

Check Text (C-245528r836815_chk)

Verify Samsung SDS EMM local accounts have been configured to prohibit password reuse for a minimum of five generations. 1. Log in to the SDS EMM console. 2. Go to Setting >> Server >> Configuration >> Manage Password History (Times). 3. Verify the Manage Password History (Times) is set to 5. If the Manage Password History (Times) is not set to 5, this is a finding.

Fix Text (F-48759r835015_fix)

Configure Samsung SDS EMM local accounts with password maximum lifetime of 60 Days. On the MDM console, do the following: 1. Log in to the SDS EMM console. 2. Go to Setting >> Server >> Configuration >> Manage Validity Period (Days). 3. Set the Manage Validity Period (Days) to 60. 4. Save setting.