STIGViewer Support

OpenShift must configure Alert Manger Receivers to notify SA and ISSO of all audit failure events requiring real-time alerts.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-257559CNTR-OS-000690SV-257559r961401_ruleCCI-001858medium
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less). Satisfies: SRG-APP-000360-CTR-000815, SRG-APP-000474-CTR-001180
STIGDate
Red Hat OpenShift Container Platform 4.x Security Technical Implementation Guide2026-08-24

Related Frameworks

2 mappings across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CHG-06Control Functionality Verification
0.50
MON-05.1Real-Time Alerts of Event Logging Failure
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (26) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(1)Automated System Account Management
1.00
AC-2(4)Automated Audit Actions
1.00
AU-10(2)Validate Binding of Information Producer Identity
1.00
AU-12Audit Record Generation
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-4Audit Log Storage Capacity
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00

+16 more (top 10 by confidence shown)

CCI2 mappings

Details

Check Text (C-257559r961401_chk)

Verify the AlertManager config includes a configured receiver. 1. From the Administrator perspective on the OpenShift web console, navigate to Administration >> Cluster Settings >> Configuration >> Alertmanager. 2. View the list of receivers and inspect the configuration. 3. Verify that at least one receiver is configured as either PagerDuty, Webhook, Email, or Slack according to the organizations policy. If an alert receiver is not configured according to the organizational policy, this is a finding.

Fix Text (F-61218r921619_fix)

Create an alert notification receiver. 1. From the Administrator perspective on the OpenShift web console, navigate to Administration >> Cluster Settings >> Configuration >> Alertmanager. 2. Select "Create Receiver". 3. Set the name and choose a Receiver Type. 4. Complete the form as per the organizations policy. 5. Click "Create". Refer to the following documentation for more information: https://docs.openshift.com/container-platform/4.8/monitoring/managing-alerts.html#sending-notifications-to-external-systems_managing-alerts