OpenShift must configure Alert Manger Receivers to notify SA and ISSO of all audit failure events requiring real-time alerts.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-257559 | CNTR-OS-000690 | SV-257559r961401_rule | CCI-001858 | medium |
| Description | ||||
| It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less). Satisfies: SRG-APP-000360-CTR-000815, SRG-APP-000474-CTR-001180 | ||||
| STIG | Date | |||
| Red Hat OpenShift Container Platform 4.x Security Technical Implementation Guide | 2026-08-24 | |||
Related Frameworks
2 mappings across 3 frameworks
Related Frameworks
SCF0 mappings
No source states a mapping between these directly.
Also reachable in 3 hops (2) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- SCF Secure Traceability Relationship Mapping (STRM)2026.2intersects
NIST 800-530 mappings
No source states a mapping between these directly.
Also reachable in 2 hops (26) derived by us, not asserted by any source
Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R1intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V2R2intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3our copyintersects(normalised)
- DISA STIG Benchmark (XCCDF)V1R3intersects(normalised)
- DISA CCI List2025-01-23equal to(normalised)
+16 more (top 10 by confidence shown)
CCI2 mappings
CCI-001858
1.00
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
CCI-002702
1.00
- DISA STIG Benchmark (XCCDF)V2R7intersects(normalised)
Details
Check Text (C-257559r961401_chk)
Verify the AlertManager config includes a configured receiver.
1. From the Administrator perspective on the OpenShift web console, navigate to Administration >> Cluster Settings >> Configuration >> Alertmanager.
2. View the list of receivers and inspect the configuration.
3. Verify that at least one receiver is configured as either PagerDuty, Webhook, Email, or Slack according to the organizations policy.
If an alert receiver is not configured according to the organizational policy, this is a finding.
Fix Text (F-61218r921619_fix)
Create an alert notification receiver.
1. From the Administrator perspective on the OpenShift web console, navigate to Administration >> Cluster Settings >> Configuration >> Alertmanager.
2. Select "Create Receiver".
3. Set the name and choose a Receiver Type.
4. Complete the form as per the organizations policy.
5. Click "Create".
Refer to the following documentation for more information:
https://docs.openshift.com/container-platform/4.8/monitoring/managing-alerts.html#sending-notifications-to-external-systems_managing-alerts