STIGViewer Support

OpenShift must use internal system clocks to generate audit record time stamps.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-257525CNTR-OS-000230SV-257525r960927_ruleCCI-000159medium
Description
Knowing when a sequence of events for an incident occurred is crucial to understand what may have taken place. Without a common clock, the components generating audit events could be out of synchronization and would then present a picture of the event that is warped and corrupted. To give a clear picture, it is important that the container platform and its components use a common internal clock.
STIGDate
Red Hat OpenShift Container Platform 4.x Security Technical Implementation Guide2026-08-24

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (18) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(1)Automated System Account Management
1.00
AC-2(4)Automated Audit Actions
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-6(4)Central Review and Analysis
1.00

+8 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-257525r960927_chk)

Verify the chronyd service is enabled and active by executing the following: for node in $(oc get node -oname); do oc debug $node -- chroot /host /bin/bash -c 'echo -n "$HOSTNAME "; systemctl is-enabled chronyd.service; systemctl is-active chronyd.service' 2>/dev/null; done If the auditd service is not "enabled" and "active", this is a finding.

Fix Text (F-61184r921517_fix)

Apply the machine config to use internal system clocks for audit records by executing the following: for mcpool in $(oc get mcp -oname | sed "s:.*/::" ); do echo "apiVersion: machineconfiguration.openshift.io/v1 kind: MachineConfig metadata: name: 80-chronyd-service-enable-$mcpool labels: machineconfiguration.openshift.io/role: $mcpool spec: config: ignition: version: 3.1.0 systemd: units: - name: chronyd.service enabled: true " | oc apply -f - done