STIGViewer Support

OL 9 must securely compare internal information system clocks at least every 24 hours.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-271699OL09-00-002323SV-271699r1091809_ruleCCI-004923medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Depending on the infrastructure being used the "pool" directive may not be supported. Authoritative time sources include the United States Naval Observatory (USNO) time servers, a time server designated for the appropriate DOD network (NIPRNet/SIPRNet), and/or the Global Positioning System (GPS). Satisfies: SRG-OS-000355-GPOS-00143, SRG-OS-000356-GPOS-00144, SRG-OS-000359-GPOS-00146
STIGDate
Oracle Linux 9 Security Technical Implementation Guide2026-02-17

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-271699r1091809_chk)

Verify that OL 9 securely compares internal information system clocks at least every 24 hours with an NTP server with the following command: $ grep maxpoll /etc/chrony.conf server 0.us.pool.ntp.mil iburst maxpoll 16 If the "maxpoll" option is set to a number greater than 16 or the line is commented out, this is a finding. Verify the "chrony.conf" file is configured to an authoritative DOD time source by running the following command: $ grep -i server /etc/chrony.conf server 0.us.pool.ntp.mil If the parameter "server" is not set or is not set to an authoritative DOD time source, this is a finding.

Fix Text (F-75656r1091808_fix)