OL 9 must be configured so that successful/unsuccessful uses of the shutdown command generate an audit record.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-271576OL09-00-000745SV-271576r1092570_ruleCCI-000172medium
Description
Misuse of the shutdown command may cause availability issues for the system.
STIGDate
Oracle Linux 9 Security Technical Implementation Guide2025-05-08

Details

Check Text (C-271576r1092570_chk)

Verify that OL 9 is configured to audit the execution of the shutdown command with the following command: $ sudo auditctl -l | grep shutdown -a always,exit -F path=/usr/sbin/shutdown -F perm=x -F auid>=1000 -F auid!=unset -k privileged-shutdown If the command does not return a line or the line is commented out, this is a finding.

Fix Text (F-75533r1092569_fix)

Configure the audit system to generate an audit event for any successful/unsuccessful uses of the shutdown command by adding or updating the following rule in the "/etc/audit/rules.d/audit.rules" file: -a always,exit -F path=/usr/sbin/shutdown -F perm=x -F auid>=1000 -F auid!=unset -k privileged-shutdown The audit daemon must be restarted for the changes to take effect. Restart auditd: $ sudo service auditd restart