OL 9 must have the chrony package installed.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-271501OL09-00-000310SV-271501r1091215_ruleCCI-004923medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.
STIGDate
Oracle Linux 9 Security Technical Implementation Guide2025-05-08

Details

Check Text (C-271501r1091215_chk)

Verify that OL 9 has the chrony package installed with the following command: $ dnf list --installed chrony Installed Packages chrony.x86_64 4.5-1.0.2.el9 @ol9_baseos_latest If the chrony package is not installed, this is a finding.

Fix Text (F-75458r1091214_fix)

Install the chrony package with the following command: $ sudo dnf install -y chrony