STIGViewer Support

The Omnissa WS1 UEM server must enforce a 60-day maximum password lifetime restriction.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-284354OMW1-00-012200SV-284354r1224097_ruleCCI-004066medium
Description
Any password, no matter how complex, can eventually be cracked. Therefore, passwords need to be changed at specific intervals. One method of minimizing this risk is to use complex passwords and periodically change them. If the application does not limit the lifetime of passwords and force users to change their passwords, there is the risk that the system and/or application passwords could be compromised. This requirement does not include emergency administration accounts, which are meant for access to the application in case of failure. These accounts are not required to have maximum password lifetime restrictions. Satisfies: FMT_SMF.1(2)b Reference: PP-MDM-431024
STIGDate
Omnissa WS1 UEM Server Security Technical Implementation Guide2026-06-15

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-10Authenticator Management
0.50
IAC-10.1Password-Based Authentication
0.50
IAC-10.4Automated Support For Password Strength
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (61) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-12Session Termination
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00

+51 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.5.10
1.00
3.5.7
1.00
3.5.8
1.00
3.5.9
1.00
CCI1 mapping

Details

Check Text (C-284354r1224097_chk)

Authenticate to the Workspace ONE UEM console as an administrator. Navigate to Groups & Settings >> All Settings >> Admin >> Console Security >> Passwords. If "Password Expiration Period (days)" is not set to "60" (or less), this is a finding. Note: If this procedure is not seen on the console, the Cloud Service Provider (CSP) is managing the setting. Contact the CSP to review the required setting.

Fix Text (F-88823r1211924_fix)

Authenticate to the Workspace ONE UEM console as an administrator. 1. Navigate to Groups & Settings >> All Settings >> Admin >> Console Security >> Passwords. 2. Configure "Password Expiration Period (days)" to "60" or less. 3. Click "Save". Note: If this procedure is not seen on the console, the CSP is managing the setting. Contact the CSP to implement the required setting.