The Omnissa WS1 UEM server must enforce a minimum 15-character password length.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-284349 | OMW1-00-011400 | SV-284349r1224092_rule | CCI-004066 | medium |
| Description | ||||
| The shorter the password, the lower the number of possible combinations that need to be tested before the password is compromised. Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. Password length is one factor of several that helps to determine strength and how long it takes to crack a password. The shorter the password, the lower the number of possible combinations that need to be tested before the password is compromised. Use of more characters in a password helps to exponentially increase the time and/or resources required to compromise the password. Satisfies: FMT_SMF.1(2)b Reference: PP-MDM-431018 | ||||
| STIG | Date | |||
| Omnissa WS1 UEM Server Security Technical Implementation Guide | 2026-06-15 | |||
Details
Check Text (C-284349r1224092_chk)
Authenticate to the Workspace ONE UEM console as an administrator.
Navigate to Groups & Settings >> All Settings >> Admin >> Console Security >> Passwords.
If "Minimum Password Length" is not set to "15", this is a finding.
Note: If this procedure is not seen on the console, the Cloud Service Provider (CSP) is managing the setting. Contact the CSP to review the required setting.
Fix Text (F-88818r1211915_fix)
Authenticate to the Workspace ONE UEM console as an administrator.
Navigate to Groups & Settings >> All Settings >> Admin >> Console Security >> Passwords.
Configure "Minimum Password Length" to "15".