STIGViewer Support

The Omnissa WS1 UEM Agent must be configured to enable the following function: Read audit logs of the managed endpoint device: Android.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-284237OMW1-00-100350SV-284237r1223978_ruleCCI-000169medium
Description
Audit logs and alerts enable monitoring of security-relevant events and subsequent forensics when breaches occur. They help identify when the security posture of the device is not as expected. This enables the UEM administrator to take an appropriate remedial action. Satisfies: FMT_SMF_EXT.4.1 Reference: PP-UEM-401005 Satisfies: SRG-APP-000089-UEM-100012, SRG-APP-000358-UEM-100013
STIGDate
Omnissa WS1 UEM Agent Security Technical Implementation Guide2026-06-15

Related Frameworks

2 mappings across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (16) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.1Intrusion Detection & Prevention Systems (IDS & IPS)
1.00
MON-01.3Inbound & Outbound Communications Traffic
1.00
MON-01.4System Generated Alerts
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
MON-01.8Security Event Monitoring
1.00
MON-03Content of Event Logs
1.00

+6 more (top 10 by confidence shown)

NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (63) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-16Security and Privacy Attributes
1.00
AC-17(1)Monitoring and Control
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-3(3)Mandatory Access Control
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AC-7Unsuccessful Logon Attempts
1.00

+53 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.1
1.00
3.3.2
1.00
CCI2 mappings
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

12 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-284237r1223978_chk)

Review the MDM Agent documentation and configuration settings to determine if the following function is enabled: Read audit logs of the MD. This validation procedure is performed on the MDM Administration Console. On the MDM console, do the following: 1. Authenticate to the Workspace ONE UEM console as the administrator. 2. Navigate to Groups & Settings >> All Settings >> Devices & Users >> General >> Privacy. Enable "Request Device Log" in the privacy settings. If "Request Device Log" is present, then no device log is being requested from the MD, and this is a finding.

Fix Text (F-88706r1211875_fix)

Configure the MDM Agent to enable the following function: Read audit logs of the MD. On the MDM console, do the following: 1. Authenticate to the Workspace ONE UEM console as the administrator. 2. Navigate to Groups & Settings >> All Settings >> Devices & Users >> General >> Privacy. Enable "Request Device Log" in the privacy settings. 3. Select "Save".