STIGViewer Support

Nutanix AOS must configure Network Time Protocol (NTP).

Export this STIG:

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-279450NXAC-AS-000051SV-279450r1265228_ruleCCI-004922medium
Description
Time synchronization of system clocks is essential for the correct execution of many system services, including identification and authentication processes that involve certificates and time-of-day restrictions as part of access control. Denial of service or failure to deny expired credentials may result without properly synchronized clocks within and between systems and system components. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. The granularity of time measurements refers to the degree of synchronization between system clocks and reference clocks, such as clocks synchronizing within hundreds of milliseconds or tens of milliseconds. Organizations may define different time granularities for system components. Time service can be critical to other security capabilities such as access control and identification and authentication, depending on the nature of the mechanisms used to support the capabilities. Satisfies: SRG-APP-000920-AS-000320, SRG-APP-000371-AS-000077
STIGDate
Nutanix Acropolis Application Server Security Technical Implementation Guide2026-08-27

Related Frameworks

2 mappings across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (15) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AC-2(3)Disable Accounts
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
AU-9Protection of Audit Information
1.00
CM-6Configuration Settings
1.00
CM-6(1)Automated Management, Application, and Verification
1.00
IA-2(6)Access to Accounts —separate Device
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00

+5 more (top 10 by confidence shown)

CCI2 mappings

Details

Check Text (C-279450r1265228_chk)

Confirm the Prism Element is configured to use an authoritative NTP source. 1. Log in to Prism Element. 2. Click the gear icon in the upper-right corner. 3. Navigate to "NTP Servers". 4. Verify external NTP servers have been configured. If external NTP sources are not configured, this is a finding.

Fix Text (F-83908r1191135_fix)

Configure the Prism Element to use an authoritative NTP time source. 1. Log in to Prism Element. 2. Click the gear icon in the upper-right corner. 3. Navigate to "NTP Servers". 4. Configure an authoritative NTP server.