STIGViewer Support

Nutanix AOS must use internal system clocks to generate time stamps for log records.

Export this STIG:

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-279426NXAC-AS-000019SV-279426r1265206_ruleCCI-000159medium
Description
Without using an approved and synchronized time source on the systems, events cannot be accurately correlated and analyzed to determine what is transpiring within the application server. If an event has been triggered on the network and the application server is not configured with the correct time, the event may be seen as insignificant, when in reality the events are related and may have a larger impact across the network. Synchronization of system clocks is needed to correctly correlate the timing of events that occur across multiple systems. Determining the correct time a particular event occurred on a system, via time stamps, is critical when conducting forensic analysis and investigating system events. Application servers must use the internal system clock when generating time stamps and log records.
STIGDate
Nutanix Acropolis Application Server Security Technical Implementation Guide2026-08-27

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (18) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(1)Automated System Account Management
1.00
AC-2(4)Automated Audit Actions
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-6(4)Central Review and Analysis
1.00

+8 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-279426r1265206_chk)

Confirm Prism Element is set to use an authoritative time source to generate time stamps for log records. 1. Log in to Prism Element. 2. Select the gear icon in upper-right corner. 3. Select "NTP Servers" from the left navigation pane. If no authoritative time sources are listed, this is a finding.

Fix Text (F-83884r1191063_fix)

Configure Prism Element to use organization-identified authoritative time sources. 1. Log in to Prism Element. 2. Select the gear icon in upper-right corner. 3. Select "NTP Servers" from the left navigation pane. 4. Enter authoritative time sources, then click "Add". Multiple time sources can be added.