The Nokia Provider Edge (PE) router providing Multiprotocol Label Switching (MPLS) Virtual Private Wire Service (VPWS) must be configured to have the appropriate virtual circuit identification (VC ID) for each attachment circuit.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-283824NOKI-RT-000060SV-283824r1203721_ruleCCI-000366high
Description
VPWS is a layer 2 virtual private network (L2VPN) technology that provides a virtual circuit between two PE routers to forward layer 2 frames between two customer-edge routers or switches through an MPLS-enabled IP core. The ingress PE router (virtual circuit head-end) encapsulates Ethernet frames inside MPLS packets using label stacking and forwards them across the MPLS network to the egress PE router (virtual circuit tail-end). During a virtual circuit setup, the PE routers exchange VC label bindings for the specified VC ID. The VC ID specifies a pseudowire associated with an ingress and egress PE router and the customer-facing attachment circuits. To guarantee that all frames are forwarded onto the correct pseudowire and to the correct customer and attachment circuits, the correct VC ID must be configured for each attachment circuit.
STIGDate
Nokia Service Router OS 25.x Router Security Technical Implementation Guide2026-06-15

Details

Check Text (C-283824r1203721_chk)

Review the ingress and egress PE router configuration for each virtual circuit that has been provisioned and verify the correct and unique VCID has been configured for the appropriate attachment circuit. Use the following command to verify "SvcId" and "VCID" fields and confirm the correct VC ID has been configured for the correct service, as shown in the example below: - show router ldp bindings services | match "VCId" post-lines 5 Type VCId SDPId LMTU Peer SvcId IngLbl RMTU EgrLbl ------------------------------------------------------------------------------- E-Eth 10 40 1500 4.4.4.4:0 10 524282U 1500 Note: Ethernet over MPLS in VLAN mode transports Ethernet traffic from a source 802.1Q VLAN to a destination 802.1Q VLAN over a core MPLS network. The VC ID must be unique and the same on each end as it is used to connect the endpoints of the VC. If the correct VC ID has not been configured on both routers, this is a finding.

Fix Text (F-88294r1203720_fix)

Assign globally unique VC IDs for each virtual circuit and configure the attachment circuits with the appropriate VC ID. Configure the same VC ID on both ends of the VC, as shown in the example below: - configure service epipe 10 customer 1 create - config>service>epipe# spoke-sdp 40:10 create - config>service>epipe>spoke-sdp# exit - config>service>epipe# sap 1/1/c3/1 create - config>service>epipe>sap# exit all