STIGViewer Support

The Nokia router must be configured to compare the internal system clocks on an organization-defined frequency with an organization-defined authoritative time source.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-283795NOKI-ND-001040SV-283795r1203430_ruleCCI-004923medium
Description
Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.
STIGDate
Nokia Service Router OS 25.x Network Device Management Security Technical Implementation Guide2026-06-15

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-283795r1203430_chk)

Verify the Nokia router is configured to compare the internal system clocks on an organization-defined frequency with organization defined authoritative time source. Verify NTP server is configured: - show system ntp detail NTP Status Configured : Yes Stratum : 3 Admin Status : up Oper Status : up Server Enabled : No Server Authenticate : No Clock Source : 10.1.0.158 Auth Check : Yes Auth Keychain : Auth Errors : 0 Auth Errors Ignored : 0 Auth Key Id Errors : 0 Auth Key Type Errors : 0 Current Date & Time: 2025/12/02 13:45:31 UTC If the Nokia router is not configured to compare the internal system clocks on an organization-defined frequency with an organization-defined authoritative time source, this is a finding.

Fix Text (F-88265r1203429_fix)

Configure the Nokia router to compare the internal system clocks on an organization-defined frequency with an organization-defined authoritative time source. Configure NTP server to be used for timing using the command below: - configure system time ntp server <NTP server ip address>authentication-key <key id> key <key> type message-digest