STIGViewer Support

The Nokia router must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-283778NOKI-ND-000650SV-283778r1203581_ruleCCI-001890medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
STIGDate
Nokia Service Router OS 25.x Network Device Management Security Technical Implementation Guide2026-06-15

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07Time Stamps
0.50
SEA-20Clock Synchronization
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (26) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-17(9)Disconnect or Disable Access
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00
AU-14(2)Capture and Record Content
1.00
AU-3Content of Audit Records
1.00

+16 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.7
1.00
CCI1 mapping

Details

Check Text (C-283778r1203581_chk)

Verify a time zone is configured on the device, as shown in the example below: - show log log-id <log id> show log log-id 101 498 2025/11/10 18:35:48.230 UTC MINOR: USER #2011 management admin "User from 10.2.0.2: NFS-Sr-2s# configure log syslog 1" If the Nokia router does not record time stamps for audit records that can be mapped to UTC or GMT, this is a finding.

Fix Text (F-88248r1203378_fix)

Configure the Nokia router to record time stamps for audit records that can be mapped to UTC or GMT using the commands below: - configure log log-id <log id> - time-format utc