The Nokia router must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-283778 | NOKI-ND-000650 | SV-283778r1203581_rule | CCI-001890 | medium |
| Description | ||||
| If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. | ||||
| STIG | Date | |||
| Nokia Service Router OS 25.x Network Device Management Security Technical Implementation Guide | 2026-06-15 | |||
Details
Check Text (C-283778r1203581_chk)
Verify a time zone is configured on the device, as shown in the example below:
- show log log-id <log id>
show log log-id 101
498 2025/11/10 18:35:48.230 UTC MINOR: USER #2011 management admin
"User from 10.2.0.2: NFS-Sr-2s# configure log syslog 1"
If the Nokia router does not record time stamps for audit records that can be mapped to UTC or GMT, this is a finding.
Fix Text (F-88248r1203378_fix)
Configure the Nokia router to record time stamps for audit records that can be mapped to UTC or GMT using the commands below:
- configure log log-id <log id>