ONTAP must be configured to synchronize internal information system clocks using redundant authoritative time sources.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-246936NAOT-AU-000004SV-246936r1015268_ruleCCI-004928medium
Description
The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions. Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891. DOD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: a time server designated for the appropriate DOD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.
STIGDate
NetApp ONTAP DSC 9.x Security Technical Implementation Guide2026-05-23

Related Frameworks

2 mappings across 2 frameworks
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (7) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AU-8Time Stamps
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI2 mappings

Details

Check Text (C-246936r1015268_chk)

Use "cluster time-service ntp server show" to view the current network time protocol configuration for ONTAP and ensure at least two ntp servers are defined. If ONTAP is not configured to synchronize internal information system clocks using redundant authoritative time sources, this is a finding.

Fix Text (F-50322r860679_fix)