Description
Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior. Enabling PowerShell Transcription will record detailed information from the processing of PowerShell commands and scripts. This can provide additional detail when malware has run on a system.
STIGDate
Microsoft Windows Server 2025 Security Technical Implementation Guide2026-02-20

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (20) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-02Secure Baseline Configurations
1.00
CRY-01Use of Cryptographic Controls
1.00
DCH-01Data Protection
1.00
HRS-02Position Categorization
1.00
HRS-11Separation of Duties (SoD)
1.00
IAC-01Identity & Access Management (IAM)
1.00
IAC-01.2Authenticate, Authorize and Audit (AAA)
1.00
IAC-02Identification & Authentication for Organizational Users
1.00
IAC-03Identification & Authentication for Non-Organizational Users
1.00
IAC-04Identification & Authentication for Devices
1.00

+10 more (top 10 by confidence shown)

NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (93) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-16Security and Privacy Attributes
1.00
AC-17(1)Monitoring and Control
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-17(2)Protection of Confidentiality and Integrity Using Encryption
1.00
AC-18(1)Authentication and Encryption
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00

+83 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.1.1
1.00
3.1.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

17 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-278131r1181099_chk)

If the following registry value does not exist or is not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \SOFTWARE\Policies\Microsoft\Windows\PowerShell\Transcription\ Value Name: EnableTranscripting Value Type: REG_DWORD Value: 1

Fix Text (F-82566r1181098_fix)

Configure the policy value for Computer Configuration >> Administrative Templates >> Windows Components >> Windows PowerShell >> "Turn on PowerShell Transcription" to "Enabled". Specify the Transcript output directory to point to a Central Log Server or another secure location to prevent user access.