Windows Server 2022 Diagnostic Data must be configured to send "required diagnostic data" or "optional diagnostic data".

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-254356WN22-CC-000250SV-254356r991589_ruleCCI-000366medium
Description
Some features may communicate with the vendor, sending system information or downloading data or components for the feature. Limiting this capability will prevent potentially sensitive information from being sent outside the enterprise. The "send required diagnostic data" option for Allow Diagnostic Data configures the lowest amount of data, effectively none outside of the Malicious Software Removal Tool (MSRT), Defender, and Diagnostic Data client settings. "Optional Diagnostic Data" sends basic diagnostic and usage data and may be required to support some Microsoft services.
STIGDate
Microsoft Windows Server 2022 Security Technical Implementation Guide2026-02-13

Related Frameworks

4 paths across 3 frameworks
NIST 800-531 mapping
CM-6
1.00
  • DISA · V2R8 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.4.1
1.00
  • DISA · V2R8 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.4.2
1.00
  • DISA · V2R8 · disa_xccdf · related
  • DISA · 2025-01-23 · disa_cci_list · equivalent
  • NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000366
1.00
  • DISA · V2R8 · disa_xccdf · related

Details

Check Text (C-254356r991589_chk)

If the following registry value does not exist or is not configured as specified, this is a finding: Registry Hive: HKEY_LOCAL_MACHINE Registry Path: \SOFTWARE\Policies\Microsoft\Windows\DataCollection\ Value Name: AllowTelemetry Type: REG_DWORD Value: 0x00000001 (1), 0x00000003 (3)

Fix Text (F-57792r902887_fix)

Configure the policy value for Computer Configuration >> Administrative Templates >> Windows Components >> Data Collection and Preview Build >> Allow Diagnostic Data to "Enabled" with "Send required diagnostic data" selected or "Send optional diagnostic data".