MarkLogic Server must be able to generate audit records when security objects are accessed.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-220390 | ML09-00-009300 | SV-220390r961791_rule | CCI-000172 | medium |
| Description | ||||
| Changes to the security configuration must be tracked. This requirement applies to situations where security data is retrieved or modified via data manipulation operations, as opposed to via specialized security functionality. | ||||
| STIG | Date | |||
| MarkLogic Server v9 Security Technical Implementation Guide | 2024-09-04 | |||
Related Frameworks
4 paths across 3 frameworks
Related Frameworks
NIST 800-531 mapping
AU-12
1.00
- DISA · V3R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.3.1
1.00
- DISA · V3R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.3.2
1.00
- DISA · V3R2 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000172
1.00
- DISA · V3R2 · disa_xccdf · related
Details
Check Text (C-220390r961791_chk)
Review MarkLogic configuration to determine if audit records will be produced when security objects are accessed, to include reads, creations, modifications and deletions of data, and execution of logic.
Perform the fix from the MarkLogic Server Admin Interface with a user that holds administrative-level privileges.
1. Click the Groups icon.
2. Click the group in which the configuration to be checked resides (e.g., Default).
3. Click the Auditing icon on the left tree menu.
4. Verify audit enabled field is set to true. If the setting is not true, this is a finding.
5. Under the Audit Restrictions - Outcome section, verify the security-access event for auditing is set to "both". If the setting is not "both", this is a finding.
Fix Text (F-22094r401622_fix)
Configure MarkLogic to produce audit records when security objects are accessed, to include reads, creations, modifications and deletions of data, and execution of logic.
Perform the fix from the MarkLogic Server Admin Interface with a user that holds administrative-level privileges.
1. Click the Groups icon.
2. Click the group in which the configuration to be checked resides (e.g., Default).
3. Click the Auditing icon on the left tree menu.
4. Set the audit enabled field to true.
5. Enable the security-access event for auditing.
6. Under the Audit Restrictions section, enable "both" under the Outcome selection.