The Mainframe Product must compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-263687 | SRG-APP-000925-MFP-000330 | SV-263687r982605_rule | CCI-004923 | medium |
| Description | ||||
| Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network. | ||||
| STIG | Date | |||
| Mainframe Product Security Requirements Guide | 2024-12-05 | |||
Related Frameworks
2 paths across 2 frameworks
Related Frameworks
NIST 800-531 mapping
SC-45(1)
1.00
- DISA · 3 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
CCI1 mapping
CCI-004923
1.00
- DISA · 3 · disa_xccdf · related
Details
Check Text (C-263687r982605_chk)
Verify the Mainframe Product is configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.
If the Mainframe Product is not configured to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source, this is a finding.
Fix Text (F-67508r982378_fix)
Configure the Mainframe Product to compare the internal system clocks on an organization-defined frequency with organization-defined authoritative time source.