STIGViewer Support

Mainframe Products must implement cryptographic mechanisms to protect the confidentiality of nonlocal maintenance and diagnostic communications.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-205580SRG-APP-000412-MFP-000261SV-205580r961557_ruleCCI-003123medium
Description
Privileged access contains control and configuration information which is particularly sensitive, so additional protections are necessary. This is maintained by using cryptographic mechanisms to protect confidentiality. Nonlocal maintenance and diagnostic activities are those activities conducted by individuals communicating through a network, either an external network (e.g., the Internet) or an internal network. Local maintenance and diagnostic activities are those activities carried out by individuals physically present at the information system or information system component and not communicating across a network connection. The application can meet this requirement through leveraging a cryptographic module.
STIGDate
Mainframe Product Security Requirements Guide2026-05-23

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MNT-05.3Remote Maintenance Cryptographic Protection
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (26) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(1)Monitoring and Control
1.00
AC-17(2)Protection of Confidentiality and Integrity Using Encryption
1.00
AC-2(4)Automated Audit Actions
1.00
AC-4Information Flow Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-12Audit Record Generation
1.00
AU-3Content of Audit Records
1.00
AU-9(3)Cryptographic Protection
1.00
CM-5(1)Automated Access Enforcement and Audit Records
1.00
CM-6Configuration Settings
1.00

+16 more (top 10 by confidence shown)

CCI1 mapping

Details

Check Text (C-205580r961557_chk)

If the Mainframe Product has no function or capability for nonlocal maintenance, this is not applicable. Examine installation and configuration settings. If the Mainframe Product does not use FIPS 140 compliant modules to protect the confidentiality of nonlocal maintenance and diagnostic communications, this is a finding.

Fix Text (F-5846r299968_fix)

Configure the Mainframe Product to use FIPS 140 compliant modules to protect the confidentiality of nonlocal maintenance and diagnostic communications.