STIGViewer Support

The Mainframe Product must implement organization-defined automated security responses if baseline configurations are changed in an unauthorized manner.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-205565SRG-APP-000379-MFP-000186SV-205565r961458_ruleCCI-001744medium
Description
Unauthorized changes to the baseline configuration could make the system vulnerable to various attacks or allow unauthorized access to the system. Changes to information system configurations can have unintended side effects, some of which may be relevant to security. Detecting such changes and providing an automated response can help avoid unintended, negative consequences that could ultimately affect the security state of the application. Examples of security responses include, but are not limited to, the following: halting application processing; halting selected application functions; or issuing alerts/notifications to organizational personnel when there is an unauthorized modification of a configuration item.
STIGDate
Mainframe Product Security Requirements Guide2026-05-23

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CHG-02.4Automated Security Response
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AU-12Audit Record Generation
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-5(2)Real-time Alerts
1.00
AU-8Time Stamps
1.00
CM-3(5)Automated Security Response
1.00
CM-5(1)Automated Access Enforcement and Audit Records
1.00
SI-11Error Handling
1.00
SI-6Security and Privacy Function Verification
1.00
CCI1 mapping

Details

Check Text (C-205565r961458_chk)

Examine Installation configuration settings. If the Mainframe Product does not implement organization-defined automated security responses if baseline configurations are changed in an unauthorized manner, this is a finding.

Fix Text (F-5831r299923_fix)

Configure installation and/or configuration auditing settings to implement organization-defined automated security responses if baseline configurations are changed in an unauthorized manner.