STIGViewer Support

The Mainframe Product must display an explicit logoff message to users indicating the reliable termination of authenticated communications sessions.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-205537SRG-APP-000297-MFP-000008SV-205537r961227_ruleCCI-002364medium
Description
If a user cannot explicitly end an application session, the session may remain open and be exploited by an attacker; this is referred to as a zombie session. Users need to be aware of whether or not the session has been terminated. Information resources to which users gain access via authentication include, for example, local workstations, databases, and password-protected websites/web-based services. Logoff messages for web page access, for example, can be displayed after authenticated sessions have been terminated. However, for some types of interactive sessions including, for example, file transfer protocol (FTP) sessions, information systems typically send logoff messages as final messages prior to terminating sessions.
STIGDate
Mainframe Product Security Requirements Guide2026-05-23

Related Frameworks

1 mapping across 2 frameworks
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-11Device Lock
1.00
AC-12(2)Termination Message
1.00
SC-10Network Disconnect
1.00
CCI1 mapping

Details

Check Text (C-205537r961227_chk)

If the Mainframe Product has no logon capability, this requirement is not applicable. Examine the Mainframe Product configuration settings to determine whether the Mainframe Product displays an explicit logoff message. If it does not, this is a finding

Fix Text (F-5803r299845_fix)

Configure the Mainframe Product to display a specific logoff message.