The Juniper router must be configured to produce audit records containing information to establish where the events occurred.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-253996JUEX-RT-000240SV-253996r844021_ruleCCI-000132medium
Description
Without establishing where events occurred, it is impossible to establish, correlate, and investigate the events leading up to an outage or attack. To compile an accurate risk assessment and provide forensic analysis, it is essential for security personnel to know where events occurred, such as router components, modules, device identifiers, node names, and functionality. Associating information about where the event occurred within the network provides a means of investigating an attack, recognizing resource utilization or capacity thresholds, or identifying an improperly configured router.
STIGDate
Juniper EX Series Switches Router Security Technical Implementation Guide2024-06-10

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-01Continuous Monitoring
1.00
MON-01.4System Generated Alerts
1.00
MON-03Content of Event Logs
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (46) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-16Security and Privacy Attributes
1.00
AC-17(1)Monitoring and Control
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3(3)Mandatory Access Control
1.00
AC-4Information Flow Enforcement
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AU-10Non-repudiation
1.00
AU-12Audit Record Generation
1.00
AU-12(3)Changes by Authorized Individuals
1.00
AU-14(1)System Start-up
1.00

+36 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.1
1.00
3.3.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

6 NICE work roles and 5 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-253996r844021_chk)

The router must log all packets that have been dropped via the stateless firewall filter. Verify all discarding firewall filter terms are configured to send events to syslog. Note: Stateless firewall filters support "log" and "syslog" actions. The "log" action maintains a temporary list of events and the "syslog" action generates events for local storage and/or external syslog servers. Verify at least "syslog" is associated with all discarding terms. For example: [edit firewall] family inet { filter <filter name> { term 1 { from { <match conditions>; } then { log; syslog; <<< At a minimum, the 'syslog' action must be enabled for all discarding terms. discard; } } } } family inet6 { filter <filter name> { term 1 { from { <match conditions>; } then { log; syslog; <<< At a minimum, the 'syslog' action must be enabled for all discarding terms. discard; } } } } If the router fails to log all packets that have been dropped via the firewall filter, this is a finding. Verify logging is enabled for local and/or external syslog. To meet this requirement, either the "any" or the "firewall" logging facility must be enabled. Note: To reduce log sizes and to segregate entries, a separate log file for firewall entries is permissible. [edit system syslog] host <external syslog address> { any info; log-prefix <hostname>; explicit-priority; } file messages { any info; } time-format year; Log output must contain an interface name identifying where the packet was filtered. Note: Logged firewall events include the interface and cannot be configured otherwise. There is no provision for changing the log message or for removing the interface name. If the logged output does not contain an interface name identifying where the packet was filtered, this is a finding.

Fix Text (F-57399r844020_fix)

Configure the router to record the interface in the log record for packets being dropped. Example firewall filter with logging enabled: set firewall family inet filter <filter name> term 1 from <match conditions> set firewall family inet filter <filter name> term 1 then log set firewall family inet filter <filter name> term 1 then syslog <<< Must be enabled for all discarding terms set firewall family inet filter <filter name> term 1 then discard set firewall family inet6 filter <filter name> term 1 from <match conditions> set firewall family inet6 filter <filter name> term 1 then log set firewall family inet6 filter <filter name> term 1 then syslog <<< Must be enabled for all discarding terms set firewall family inet6 filter <filter name> term 1 then discard Example consolidated logging: set syslog host <external syslog address> any info set system syslog file messages any info