STIGViewer Support

The Sentry must be configured to authenticate SNMP messages using a FIPS-validated Keyed-Hash Message Authentication Code (HMAC).

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-251000MOIS-ND-000760SV-251000r1028238_ruleCCI-001967medium
Description
Without authenticating devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. Bidirectional authentication provides stronger safeguards to validate the identity of other devices for connections that are of greater risk. A local connection is any connection with a device communicating without the use of a network. A network connection is any connection with a device that communicates through a network (e.g., local area or wide area network).
STIGDate
Ivanti Sentry 9.x NDM Security Technical Implementation Guide2024-09-25

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-04Identification & Authentication for Devices
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (49) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(10)Authenticate Remote Commands
1.00
AC-17(2)Protection of Confidentiality and Integrity Using Encryption
1.00
AC-18(1)Authentication and Encryption
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-4(17)Domain Authentication
1.00
AC-7Unsuccessful Logon Attempts
1.00
AU-8Time Stamps
1.00

+39 more (top 10 by confidence shown)

CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 4 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Details

Check Text (C-251000r1028238_chk)

On the Sentry console, do the following to verify FIPS mode is enabled: 1. SSH to Sentry Server from any SSH client. 2. Enter the administrator credentials set at Sentry installation. 3. Enter "enable". 4. When prompted, enter the "enable secret" set at Sentry installation. 5. Enter "show FIPS". 6. Verify "FIPS 140 mode is enabled" is displayed. If it is not, this is a finding. Then: 1. Log in to Sentry. 2. Go to Settings >> SNMP. 3. Verify SNMP server has been added. a. If SNMP server is not added, this is a finding. b. If SNMP server is added, go to step 4. 4. Verify SNMP Control is not disabled. a. If SNMP Control is disabled, this is a finding. b. If SNMP Control is not disabled, go to step 5. 5. Verify Protocol v3 is selected. a. If Protocol v3 is not selected, this is a finding. b. If Protocol v3 is selected, go to step 6. 6. Verify the SNMP v3 User has been added. a. If SNMP v3 User has not been added, this is a finding.

Fix Text (F-54389r1004874_fix)

On Sentry console, do the following to configure FIPS mode: 1. SSH to the Sentry. 2. At the prompt, enter "enable" mode with the secret credentials. 3. Type Configure command. 4. Type FIPS. 5. Once reloaded, SSH to the Sentry. 6. Run the "show FIPS". Then: 1. Log in to Sentry. 2. Go to Settings >> SNMP. 3. Add SNMP Trap Receiver. 4. Enable SNMP Service. 5. Select Protocol v3. 6. Add SNMP v3 Users. 7. Enter User Name. 8. Select Security Level from dropdown. 9. Select AUTH Protocol from dropdown. 10. Enter AUTH Password. 11. Select Privacy Protocol from dropdown. 12. Enter Privacy Password. 13. Click "Save". 14. Enable Link Up/Down Trap. 15. Click "Apply" to save changes.