STIGViewer Support

Sentry must generate an immediate real-time alert of all audit failure events requiring real-time alerts.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-250998MOIS-ND-000690SV-250998r1028236_ruleCCI-001858low
Description
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.
STIGDate
Ivanti Sentry 9.x NDM Security Technical Implementation Guide2024-09-25

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-05.1Real-Time Alerts of Event Logging Failure
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (22) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-2(4)Automated Audit Actions
1.00
AU-12Audit Record Generation
1.00
AU-14(1)System Start-up
1.00
AU-3Content of Audit Records
1.00
AU-3(1)Additional Audit Information
1.00
AU-4Audit Log Storage Capacity
1.00
AU-4(1)Transfer to Alternate Storage
1.00
AU-5Response to Audit Logging Process Failures
1.00
AU-5(1)Storage Capacity Warning
1.00
AU-5(2)Real-time Alerts
1.00

+12 more (top 10 by confidence shown)

CCI1 mapping

Details

Check Text (C-250998r1028236_chk)

Verify the Sentry is configured to send alerts for failure events in Sentry System Manager web GUI. 1. Log in to Sentry. 2. Go to Monitoring >> Alert Configuration. 3. Verify Alert monitoring is configured. If Alert Configuration settings are not configured, this is a finding. Refer to the "Alert Configuration" section of the "Sentry 9.8.0 Guide for MobileIron Core" for more information.

Fix Text (F-54387r1004868_fix)

Configure the Sentry to send alerts for failure events in Sentry System Manager web GUI. 1. Log in to Sentry. 2. Go to Monitoring >> Alert Configuration. 3. Check "Send Notification". 4. Apply Email List. 5. Enter Alerts Per Hour. 6. Enter Batch Time Interval (min). 7. Select "Default Alert Action". 8. Apply. 9. Add Alert Notification Management. 10. Add Alert ID. 11. Add "Action" from dropdown. 12. Click "Apply" and "Save" in the top right corner. Refer to the "Alert Configuration" section of the "Sentry 9.8.0 Guide for MobileIron Core" for more information.