The ICS must be configured to record time stamps for audit records that can be mapped to Greenwich Mean Time (GMT).

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-258604IVCS-NM-000120SV-258604r961443_ruleCCI-001890medium
Description
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.
STIGDate
Ivanti Connect Secure NDM Security Technical Implementation Guide2024-09-16

Details

Check Text (C-258604r961443_chk)

In the ICS Web UI, navigate to System >> Status >> Dashboard. 1. Click the "Overview" tab. 2. Under "Appliance Details" and "System Date and Time", select "Edit". 3. Verify the "Time Zone" is set to "(GMT) Coordinated Universal Time". If the ICS must be configured to record time stamps for audit records that can be mapped to GMT, this is a finding.

Fix Text (F-62253r930499_fix)

In the ICS Web UI, navigate to System >> Status >> Dashboard. 1. Click the "Overview" tab. 2. Under "Appliance Details" and "System Date and Time", select "Edit". 3. Select "(GMT) Coordinated Universal Time". 4. Click "Save Changes".