The Infoblox system must notify the system administrator when a component failure is detected.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-233895IDNS-8X-400037SV-233895r1156945_ruleCCI-000366medium
Description
Predictable failure prevention requires organizational planning to address system failure issues. If components key to maintaining systems security fail to function, the system could continue operating in an insecure state. The organization must be prepared and the application must support requirements that specify if the application must alarm for such conditions and/or automatically shut down the application or the system. This can include conducting a graceful application shutdown to avoid losing information. Automatic or manual transfer of components from standby to active mode can occur, for example, upon detection of component failures.
STIGDate
Infoblox 8.x DNS Security Technical Implementation Guide2026-06-03

Related Frameworks

2 mappings across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (8) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-01Configuration Management Program
1.00
END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
CFG-02Secure Baseline Configurations
0.50
CFG-02.7Approved Configuration Deviations
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (100) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-12Session Termination
1.00
AC-16(1)Dynamic Attribute Association
1.00
AC-17(1)Monitoring and Control
1.00
AC-2Account Management
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-24(1)Transmit Access Authorization Information
1.00
AC-25Reference Monitor
1.00

+90 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.4.1
1.00
3.4.2
1.00
CCI2 mappings
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (5) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

PR.PSPlatform Security
0.50

Who does this work

10 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-233895r1156945_chk)

Infoblox systems are capable of providing notifications via remote SYSLOG, SNMP, and SMTP. 1. Navigate to Grid >> Grid Manager >> Grid Properties, or System >> System Manager >> System Properties if using a stand-alone configuration. 2. Select the "Monitoring" tab. 3. Verify that "Log to External Syslog Servers" is enabled and an External Syslog Server is configured. 4. When complete, click "Cancel" to exit the "Properties" screen. If no external notifications are enabled, this is a finding.

Fix Text (F-37045r611206_fix)

1. Navigate to Grid >> Grid Manager >> Grid Properties, or System >> System Manager >> System Properties if using a stand-alone configuration. 2. Select the Monitoring tab. 3. Enable "Log to External Syslog Servers" using the check box. 4. Configure an "External Syslog Server". 5. When complete, click "Save & Close" to save the changes and exit the "Properties" screen. 6. Perform a service restart if necessary. 7. Review the SYSLOG data on the remote SYSLOG server to validate operation.