STIGViewer Support

The IBM z/OS SNTP daemon (SNTPD) must be active.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-224023TSS0-OS-000270SV-224023r1038944_ruleCCI-004923medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
STIGDate
IBM z/OS TSS Security Technical Implementation Guide2025-06-24

Related Frameworks

1 mapping across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (9) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
CM-6Configuration Settings
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00
SC-45System Time Synchronization
1.00
SC-45(1)Synchronization with Authoritative Time Source
1.00
SC-45(2)Secondary Authoritative Time Source
1.00
CCI1 mapping

Details

Check Text (C-224023r1038944_chk)

From UNIX System Services ISPF Shell, navigate to ribbon select tools. Select option 1 - Work with Processes. If SNTP Daemon (SNTPD) is not active, this is a finding.

Fix Text (F-25684r868994_fix)

Obtain a copy of this sample procedure from SEZAINST and store it in one of your PROCLIB concatenation data sets. Perform the following step to start SNTPD as a procedure: Invoke the procedure using the system operator start command. The following sample, SEZAINST(SNTPD), shows how to start SNTPD as a procedure: //* //* Sample procedure for the Simple Network Time Protocol (SNTP) //* //* z/OS Communications Server Version 1 Release 13 //* SMP/E Distribution Name: SEZAINST(EZASNPRO) //* //* Copyright: Licensed Materials - Property of IBM //* 5650-ZOS //* Copyright IBM Corp. 2002, 2015 //* //* Status: CSV2R2 //* //SNTPD EXEC PGM=SNTPD,REGION=4096K,TIME=NOLIMIT, // PARM='/ -d' //SYSPRINT DD SYSOUT=*,DCB=(RECFM=F,LRECL=132,BLKSIZE=132) //SYSIN DD DUMMY //SYSERR DD SYSOUT=* //SYSOUT DD SYSOUT=*,DCB=(RECFM=F,LRECL=132,BLKSIZE=132) //CEEDUMP DD SYSOUT=* //SYSABEND DD SYSOUT=*