Description
Specific PPT designated program modules possess significant security bypass capabilities. Unauthorized access could result in the compromise of the operating system environment, ACP, and customer data. Satisfies: SRG-OS-000080-GPOS-00048, SRG-OS-000259-GPOS-00100, SRG-OS-000324-GPOS-00125
STIGDate
IBM z/OS RACF Security Technical Implementation Guide2026-03-09

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (20) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-02Secure Baseline Configurations
1.00
CRY-01Use of Cryptographic Controls
1.00
DCH-01Data Protection
1.00
HRS-02Position Categorization
1.00
HRS-11Separation of Duties (SoD)
1.00
IAC-01Identity & Access Management (IAM)
1.00
IAC-01.2Authenticate, Authorize and Audit (AAA)
1.00
IAC-02Identification & Authentication for Organizational Users
1.00
IAC-03Identification & Authentication for Non-Organizational Users
1.00
IAC-04Identification & Authentication for Devices
1.00

+10 more (top 10 by confidence shown)

NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (93) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-16Security and Privacy Attributes
1.00
AC-17(1)Monitoring and Control
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-17(2)Protection of Confidentiality and Integrity Using Encryption
1.00
AC-18(1)Authentication and Encryption
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00

+83 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.1.1
1.00
3.1.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

17 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-223650r1137691_chk)

Review program entries in the IBM Program Properties Table (PPT). You may use a third-party product to examine these entries however, to determine program entries issue the following command from an ISPF command line: TSO ISRDDN LOAD IEFSDPPT Press Enter. For each module identified in the "eyecatcher" if all of the following are untrue, this is not a finding. If any of the following is true, this is a finding. -The ACP data set rules for libraries that contain PPT modules do not restrict WRITE or greater access to only z/OS systems programming personnel. -The ACP data set rules for libraries that contain PPT modules do not specify that all WRITE or greater access will be logged.

Fix Text (F-25311r514640_fix)

Configure the WRITE or greater access to libraries containing PPT modules to be limited to system programmers only and all WRITE or greater access is logged.