IBM RACF must limit Write or greater access to libraries that contain PPT modules to system programmers only.
Overview
| Finding ID | Version | Rule ID | IA Controls | Severity |
| V-223650 | RACF-ES-000020 | SV-223650r958472_rule | CCI-000213 | low |
| Description | ||||
| Specific PPT designated program modules possess significant security bypass capabilities. Unauthorized access could result in the compromise of the operating system environment, ACP, and customer data. Satisfies: SRG-OS-000080-GPOS-00048, SRG-OS-000259-GPOS-00100, SRG-OS-000324-GPOS-00125 | ||||
| STIG | Date | |||
| IBM z/OS RACF Security Technical Implementation Guide | 2025-06-24 | |||
Related Frameworks
4 paths across 3 frameworks
Related Frameworks
NIST 800-531 mapping
AC-3
1.00
- DISA · 9 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
NIST 800-1712 mappings
3.1.1
1.00
- DISA · 9 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
3.1.2
1.00
- DISA · 9 · disa_xccdf · related
- DISA · 2025-01-23 · disa_cci_list · equivalent
- NIST · Rev 2 (Feb 2020, errata Jan 2021) · nist_800_171_app_d · equivalent
CCI1 mapping
CCI-000213
1.00
- DISA · 9 · disa_xccdf · related
Details
Check Text (C-223650r958472_chk)
Review program entries in the IBM Program Properties Table (PPT). You may use a third-party product to examine these entries however, to determine program entries issue the following command from an ISPF command line:
TSO ISRDDN LOAD IEFSDPPT
Press Enter.
For each module identified in the "eyecatcher" if all of the following are untrue, this is not a finding.
If any of the following is true, this is a finding.
-The ACP data set rules for libraries that contain PPT modules do not restrict WRITE or greater access to only z/OS systems programming personnel.
-The ACP data set rules for libraries that contain PPT modules do not specify that all WRITE or greater access will be logged.
Fix Text (F-25311r514640_fix)
Configure the WRITE or greater access to libraries containing PPT modules to be limited to system programmers only and all WRITE or greater access is logged.