STIGViewer Support

IBM zOS inapplicable PPT entries must be invalidated.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-223785RACF-OS-000290SV-223785r958478_ruleCCI-000381medium
Description
It is detrimental for operating systems to provide, or install by default, functionality exceeding requirements or mission objectives. These unnecessary capabilities or services are often overlooked and therefore may remain unsecured. They increase the risk to the platform by providing additional attack vectors. Operating systems are capable of providing a wide variety of functions and services. Some of the functions and services, provided by default, may not be necessary to support essential organizational operations (e.g., key missions, functions). Examples of non-essential capabilities include, but are not limited to, games, software packages, tools, and demonstration software, not related to requirements or providing a wide array of functionality not required for every mission, but which cannot be disabled. Invalid or inapplicable PPT entries exist, a venue is provided for the introduction of trojan horse modules with security bypass capabilities.
STIGDate
IBM z/OS RACF Security Technical Implementation Guide2026-06-03

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

CFG-01Configuration Management Program
1.00
CFG-03Least Functionality
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (36) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-11Device Lock
1.00
AC-17(1)Monitoring and Control
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-17(9)Disconnect or Disable Access
1.00
AC-18(1)Authentication and Encryption
1.00
AC-2(1)Automated System Account Management
1.00
AC-3Access Enforcement
1.00
AC-4Information Flow Enforcement
1.00
AU-12Audit Record Generation
1.00
AU-3Content of Audit Records
1.00

+26 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.4.6
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

5 NICE work roles and 5 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-223785r958478_chk)

Review program entries in the IBM Program Properties Table (PPT). You may use a third-party product to examine these entries; however, to determine program entries, issue the following command from an ISPF command line: TSO ISRDDN LOAD IEFSDPPT Interpret the display as follows: Examine contents at offset 8 Hex 'x2' - Bypass Password Protection Hex 'x3' - Bypass Password Protection Hex 'x4' - No Dataset Integrity Hex 'x5' - No Dataset Integrity Hex 'x6' - Both Hex 'x7' - Both Determine Privilege Key at offset 9. A value of hex '70' or less indicates an elevated privilege. For each module identified in the "eyecatcher" that has BYPASS Password Protection, No Dataset Integrity, an elevated Privilege Key or any combination thereof, determine if there is a valid loaded module. Again, you may use a third-party product; otherwise, execute the following steps from an ISPF command line: TSO ISRDDN LOAD <privileged module> If the return message is "Load Failed", make sure there is an entry in PARMLIB member SCHEDxx that revokes the excessive privilege. If this is not true, this is a finding.

Fix Text (F-25446r868861_fix)

Review the PPT and define all entries associated with nonexistent or inapplicable modules as invalidated. Nullify the invalid IEFSDPPT entry by ensuring that there is a corresponding SCHED entry, which confers no special attributes. Use the following recommendations and techniques to provide protection for the PPT: Review the IEFSDPPT module and all programs that IBM has, by default, placed in the PPT to validate their applicability to the execution system. Refer to the IBM z/OS MVS Initialization and Tuning Reference documentation for the version and release of z/OS installed at the individual site for the actual contents of the default IEFSDPPT. Modules for products not in use on the system will have their special privileges explicitly revoked. Do this by placing a PPT entry for each module in the SYS1.PARMLIB(SCHEDxx) member, specifying no special privileges. The PPT entry for each overridden program will be in the following format, accepting the default (unprivileged) values for the subparameters: PPT PGMNAME(<program name>) Assemble documentation regarding these PPT entries, and the ISSO will keep it on file. Include the following in the documentation: - The product and release for which the PPT entry was made - The last date this entry was reviewed to authenticate status - The reason the module's privileges are being revoked