STIGViewer Support

IBM z/OS PARMLIB CLOCKxx must have the Accuracy PARM coded properly.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-223553ACF2-OS-000170SV-223553r1001127_ruleCCI-004922medium
Description
Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time, a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints).
STIGDate
IBM z/OS ACF2 Security Technical Implementation Guide2025-06-24

Related Frameworks

2 mappings across 3 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (1) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

MON-07.1Synchronization With Authoritative Time Source
1.00
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (15) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-17(9)Disconnect or Disable Access
1.00
AC-2(3)Disable Accounts
1.00
AU-8Time Stamps
1.00
AU-8(1)Synchronization with Authoritative Time Source
1.00
AU-8(2)Secondary Authoritative Time Source
1.00
AU-9Protection of Audit Information
1.00
CM-6Configuration Settings
1.00
CM-6(1)Automated Management, Application, and Verification
1.00
IA-2(6)Access to Accounts —separate Device
1.00
IA-3(1)Cryptographic Bidirectional Authentication
1.00

+5 more (top 10 by confidence shown)

CCI2 mappings

Details

Check Text (C-223553r1001127_chk)

Refer to the CLOCKxx member of PARMLIB. If the ACCURACY parm is not coded, this is a finding. If the ACCURACY parm is coded to "1000", this is not a finding.

Fix Text (F-25214r500795_fix)

Define the CLOCKxx statement to include the ACCURACY parm set to "1000".