STIGViewer Support

The PASSWORD History Count value must be set to 10 or greater.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-256878HMC0110SV-256878r998329_ruleCCI-004061medium
Description
History Count specifies the number of previous passwords saved for each USERID and compares it with an intended new password. If there is a match with one of the previous passwords, or with the current password, it will reject the intended new password. The improper setting of any of these fields, individually or in combination with another, can compromise the security of the processing environment.
STIGDate
IBM Hardware Management Console (HMC) Security Technical Implementation Guide2024-06-24

Related Frameworks

1 mapping across 4 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (3) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

IAC-10Authenticator Management
0.50
IAC-10.1Password-Based Authentication
0.50
IAC-10.4Automated Support For Password Strength
0.50
NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (61) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-10Concurrent Session Control
1.00
AC-12Session Termination
1.00
AC-17(10)Authenticate Remote Commands
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(10)Shared and Group Account Credential Change
1.00
AC-2(11)Usage Conditions
1.00
AC-2(2)Automated Temporary and Emergency Account Management
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00

+51 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.5.10
1.00
3.5.7
1.00
3.5.8
1.00
3.5.9
1.00
CCI1 mapping

Details

Check Text (C-256878r998329_chk)

Have the system administrator (SA) display the Password Profile Task window on the Hardware Management Console and validate that the History Count is set to 10. If the History Count is less than 10, then this is a finding.

Fix Text (F-60496r998328_fix)

Have the SA go into the Password Profile and set the History Count to 10 or greater.