STIGViewer Support

The ESCON Director Application Console Event log must be enabled.

Overview

Finding IDVersionRule IDIA ControlsSeverity
V-256859HLESC030SV-256859r958442_ruleCCI-000169high
Description
The ESCON Director Console Event Log is used to record all ESCON Director Changes. Failure to create an ESCON Director Application Console Event log results in the lack of monitoring and accountability of configuration changes. In addition, its use in the execution of a contingency plan could be compromised and security degraded. NOTE: Many newer installations no longer support the ESCON Director Console. For installations not supporting the ESCON Director Console, this check is not applicable.
STIGDate
IBM Hardware Management Console (HMC) Security Technical Implementation Guide2024-06-24

Related Frameworks

1 mapping across 5 frameworks
SCF0 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (15) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

END-01Endpoint Device Management (EDM)
1.00
END-04Malicious Code Protection (Anti-Malware)
1.00
END-06Endpoint File Integrity Monitoring (FIM)
1.00
MON-01Continuous Monitoring
1.00
MON-01.1Intrusion Detection & Prevention Systems (IDS & IPS)
1.00
MON-01.3Inbound & Outbound Communications Traffic
1.00
MON-01.4System Generated Alerts
1.00
MON-01.7File Integrity Monitoring (FIM)
1.00
MON-01.8Security Event Monitoring
1.00
MON-03Content of Event Logs
1.00

+5 more (top 10 by confidence shown)

NIST 800-530 mappings

No source states a mapping between these directly.

Also reachable in 2 hops (57) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

AC-16Security and Privacy Attributes
1.00
AC-17(1)Monitoring and Control
1.00
AC-2(1)Automated System Account Management
1.00
AC-2(11)Usage Conditions
1.00
AC-2(3)Disable Accounts
1.00
AC-2(4)Automated Audit Actions
1.00
AC-3Access Enforcement
1.00
AC-3(3)Mandatory Access Control
1.00
AC-6(9)Log Use of Privileged Functions
1.00
AC-7Unsuccessful Logon Attempts
1.00

+47 more (top 10 by confidence shown)

NIST 800-1710 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (2) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

3.3.1
1.00
3.3.2
1.00
CCI1 mapping
NIST CSF 2.00 mappings

No source states a mapping between these directly.

Also reachable in 3 hops (4) derived by us, not asserted by any source

Each of these is a route we composed by chaining published mappings. No publisher states a relationship between the two endpoints.

Who does this work

12 NICE work roles and 9 EC-Council certifications.

This is an inference across published mappings, not a single claim by anyone. This check maps to a control, which maps to a Cybersecurity Framework outcome, which NIST assigns to the work roles below. EC-Council separately maps its certifications to those same roles.

A certification prepares someone for a role. It is not evidence that a holder is qualified, and neither NIST nor EC-Council has stated that any certification here addresses this check.

Work-role assignments published by NIST (NICE Framework Components 2.2.0 and the CSF 2.0 OLIR crosswalk). Certification mappings published by EC-Council.

Details

Check Text (C-256859r958442_chk)

If the ESCON Director Console is present, verify on the ESCON Director Application Console that the Event log is in use, otherwise this check is not applicable. If no Event log exists, this is a finding.

Fix Text (F-60477r890922_fix)

Ensure that an ESCON Director Application Console log is created and in use every time the system is switched on. The ESCON Director maintains an audit trail at the ESCD console’s fixed disk. This audit trail logs the time, date, and password identification when changes have been made to the ESCON Director.